Thank you for your interest in our available NSN parts 4-2545 and components on Purchasing Union. 4-2545 is described as a Transformer Power part, and it is manufactured by Tranex Inc. This component is readily available for purchase today, and our team of industry experts are on standby 24/7x365 to provide you with rapid-lead times and competitive pricing on all that we carry. To begin the purchasing process, you may submit an Instant RFQ form as provided through our website. Once it is received, a member of our staff will reach out to you in 15 minutes or less to provide a personalized quote that is crafted to fit your individual needs.
Note : We Will Not Share Your Information To Any Third Parties.
Purchasing Union is a state of the art purchasing platform, and we are a leading independent distributor of 4-2545 that cater to a diverse set of industries and applications. To ensure the quality of our inventory for our customers, we choose to only source our parts from top global manufacturers that we trust, such as Tranex Inc. We also ensure that every part is rigorously tested, inspected, and cross-referenced before being shipped. Peruse our inventory at your leisure to find a multitude of top requested parts like 5950002712187, and our team is ready to serve as your strategic sourcing partner today. (CAGE Code 17474).
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-271-2187 Item Description: Transformer Power | 5950 | 002712187 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
4-2545 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.290 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.290 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT400.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.970 INCHES MINIMUM AND 3.970 INCHES MINIMUM AND 4.030 INCHES MAXIMUM4.030 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.720 INCHES MINIMUM AND 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM2.780 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.870 INCHES MINIMUM AND 3.870 INCHES MINIMUM AND 3.930 INCHES MAXIMUM3.930 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT3 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY176.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY32.70 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 32.70 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY176.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 32.70 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY25.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | SECONDARY CURRENT HAS BEEN RECTIFIED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD |