Thank you for your interest in our available NSN parts R9346 and components on Purchasing Union. R9346 is described as a Transformer Power part, and it is manufactured by Oeco Llc. This component is readily available for purchase today, and our team of industry experts are on standby 24/7x365 to provide you with rapid-lead times and competitive pricing on all that we carry. To begin the purchasing process, you may submit an Instant RFQ form as provided through our website. Once it is received, a member of our staff will reach out to you in 15 minutes or less to provide a personalized quote that is crafted to fit your individual needs.
Note : We Will Not Share Your Information To Any Third Parties.
Purchasing Union is a state of the art purchasing platform, and we are a leading independent distributor of R9346 that cater to a diverse set of industries and applications. To ensure the quality of our inventory for our customers, we choose to only source our parts from top global manufacturers that we trust, such as Oeco Llc. We also ensure that every part is rigorously tested, inspected, and cross-referenced before being shipped. Peruse our inventory at your leisure to find a multitude of top requested parts like 5950015103802, and our team is ready to serve as your strategic sourcing partner today. (CAGE Code 98330).
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-510-3802 Item Description: Transformer Power | 5950 | 015103802 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
R9346 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPV | Mounting Facility Quantity | 4 SINGLE GROUP |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 3.610 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.650 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | Winding Operating Voltage | 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CWJS | Winding Operating Voltage | 440.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
FEAT | Special Features | TERMINALS CONSIST OF HORIZONTAL TIN-PLATED BRASS LUGS W/6-32 THREAD |
ABMK | Overall Width | 4.730 INCHES MINIMUM AND 4.750 INCHES MAXIMUM |
CRBZ | Winding Operating Current | 6.8 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ACZB | Frequency Rating | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ABTD | Mounting Slot Width | 0.280 INCHES NOMINAL SINGLE GROUP |
AXGY | Mounting Method | SLOT SINGLE GROUP |
ABHP | Overall Length | 5.480 INCHES MINIMUM AND 5.500 INCHES MAXIMUM |
AEHZ | Maximum Operating Temp | 50.0 DEG CELSIUS |
MRC | Decoded Requirement | Clear Text Reply |
BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ABKW | Overall Height | 4.540 INCHES MINIMUM AND 4.560 INCHES MAXIMUM |
ACZC | Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AARG | Reliability Indicator | NOT ESTABLISHED |
AGAV | End Item Identification | ORDALT 20351, 20352, 20353, HD-1157/S, HD-1074/SQS, HD1077/SSQ, CLR, WTR, ELEK EQPT; WSD: ARLEIGH BURKE CLASS DDG |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 4.360 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.400 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | Inclosure Type | FULLY INCLOSED |
TTQY | Terminal Type And Quantity | 4 TAB W/SCREW |