Thank you for your interest in our available NSN parts 12020 and components on Purchasing Union. 12020 is described as a Transformer Assembl part, and it is manufactured by Oeco Llc. This component is readily available for purchase today, and our team of industry experts are on standby 24/7x365 to provide you with rapid-lead times and competitive pricing on all that we carry. To begin the purchasing process, you may submit an Instant RFQ form as provided through our website. Once it is received, a member of our staff will reach out to you in 15 minutes or less to provide a personalized quote that is crafted to fit your individual needs.
Note : We Will Not Share Your Information To Any Third Parties.
Purchasing Union is a state of the art purchasing platform, and we are a leading independent distributor of 12020 that cater to a diverse set of industries and applications. To ensure the quality of our inventory for our customers, we choose to only source our parts from top global manufacturers that we trust, such as Oeco Llc. We also ensure that every part is rigorously tested, inspected, and cross-referenced before being shipped. Peruse our inventory at your leisure to find a multitude of top requested parts like 5950012542151, and our team is ready to serve as your strategic sourcing partner today. (CAGE Code 95266).
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-254-2151 Item Description: Transformer Assembl | 5950 | 012542151 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
12020 | 1 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABTB | MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL 1ST GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.187 INCHES NOMINAL 3RD GROUP |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 3RD COMPONENT |
ADAQ | BODY LENGTH | 4.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.812 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.570 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.218 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.500 INCHES NOMINAL 3RD MOUNTING FACILITY SINGLE CENTER GROUP |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 5.375 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 ALL GROUPINGS |
AXGY | MOUNTING METHOD | SLOT 3RD GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE 2ND GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 1ST GROUP |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS ALL PRIMARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS ALL SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 3 SECONDARY 3RD COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY 1ST COMPONENT AND 3 SECONDARY 1ST COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES 2ND GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES AC MAXIMUM 3RD COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES AC MAXIMUM 3RD COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC MAXIMUM 2ND COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES AC MAXIMUM 3RD COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC MAXIMUM 2ND COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.14 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 149.88 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 16.26 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 178.16 AC VOLTS NOMINAL 3RD COMPONENT 4TH SECONDARY AND 195.84 AC VOLTS NOMINAL 3RD COMPONENT 4TH SECONDARY AND 213.51 AC VOLTS NOMINAL 3RD COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 530.25 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 70.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC 2ND GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 2 CONNECTOR, RECEPTACLE |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |