Thank you for your interest in our available NSN parts 99002A8046-21 and components on Purchasing Union. 99002A8046-21 is described as a Circuit Breaker part, and it is manufactured by Marine Corps. This component is readily available for purchase today, and our team of industry experts are on standby 24/7x365 to provide you with rapid-lead times and competitive pricing on all that we carry. To begin the purchasing process, you may submit an Instant RFQ form as provided through our website. Once it is received, a member of our staff will reach out to you in 15 minutes or less to provide a personalized quote that is crafted to fit your individual needs.
Note : We Will Not Share Your Information To Any Third Parties.
Purchasing Union is a state of the art purchasing platform, and we are a leading independent distributor of 99002A8046-21 that cater to a diverse set of industries and applications. To ensure the quality of our inventory for our customers, we choose to only source our parts from top global manufacturers that we trust, such as Marine Corps. We also ensure that every part is rigorously tested, inspected, and cross-referenced before being shipped. Peruse our inventory at your leisure to find a multitude of top requested parts like 5925015017437, and our team is ready to serve as your strategic sourcing partner today. (CAGE Code 01365).
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-501-7437 Item Description: Circuit Breaker | 5925 | 015017437 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
99002a8046-21 | 5 | 2 | 7 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.250 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 35.0 AMPERES AC FIRST LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 35.0 AMPERES AC SECOND LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 35.0 AMPERES AC THIRD LOCATION |
AKPX | Pole Quantity | 4 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC FIRST LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC FOURTH LOCATION |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 70.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AJEC | Boss Height | 1.042 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
AXHR | Mounting Facility Type And Quantity | 6 THREADED STUD |
ADAT | Body Width | 2.490 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.138 INCHES |
AGAV | End Item Identification | 5895-01-467-7213 |
ADTV | Case Material | METAL |
AAQL | Body Style | |
FEAT | Special Features | 1ST POLE HAS SINGLE POLE DOUBLE THROW AUXILIARY SWITCH |
AJWX | Mounting Surface To Terminal End Distance | 2.529 INCHES NOMINAL |
ADAQ | Body Length | 3.015 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 120.0 MILLIAMPERES DC FOURTH LOCATION |
MRC | Decoded Requirement | Clear Text Reply |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT FIRST LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.000 NOMINAL AT 125 PCT FOURTH LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT SECOND LOCATION |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 63.000 NOMINAL AT 125 PCT THIRD LOCATION |
THSD | Thread Series Designator | UNC |