Thank you for your interest in our available NSN parts 7403470P2 and components on Purchasing Union. 7403470P2 is described as a Transformer Power A part, and it is manufactured by General Electric Co. This component is readily available for purchase today, and our team of industry experts are on standby 24/7x365 to provide you with rapid-lead times and competitive pricing on all that we carry. To begin the purchasing process, you may submit an Instant RFQ form as provided through our website. Once it is received, a member of our staff will reach out to you in 15 minutes or less to provide a personalized quote that is crafted to fit your individual needs.
Note : We Will Not Share Your Information To Any Third Parties.
Purchasing Union is a state of the art purchasing platform, and we are a leading independent distributor of 7403470P2 that cater to a diverse set of industries and applications. To ensure the quality of our inventory for our customers, we choose to only source our parts from top global manufacturers that we trust, such as General Electric Co. We also ensure that every part is rigorously tested, inspected, and cross-referenced before being shipped. Peruse our inventory at your leisure to find a multitude of top requested parts like 5950005180148, and our team is ready to serve as your strategic sourcing partner today. (CAGE Code 03512).
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-518-0148 Item Description: Transformer Power A | 5950 | 005180148 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
7403470p2 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.375 INCHES NOMINAL |
ADAT | BODY WIDTH | 6.625 INCHES NOMINAL |
ADAU | BODY HEIGHT | 12.750 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 7.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CRMJ | WINDING POWER RATING | 1.0 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 135.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
TTQY | TERMINAL TYPE AND QUANTITY | 3 THREADED STUD |