Thank you for your interest in our available NSN parts 10037869-1 and components on Purchasing Union. 10037869-1 is described as a Transformer Power part, and it is manufactured by Abbott Technologies Inc. This component is readily available for purchase today, and our team of industry experts are on standby 24/7x365 to provide you with rapid-lead times and competitive pricing on all that we carry. To begin the purchasing process, you may submit an Instant RFQ form as provided through our website. Once it is received, a member of our staff will reach out to you in 15 minutes or less to provide a personalized quote that is crafted to fit your individual needs.
Note : We Will Not Share Your Information To Any Third Parties.
Purchasing Union is a state of the art purchasing platform, and we are a leading independent distributor of 10037869-1 that cater to a diverse set of industries and applications. To ensure the quality of our inventory for our customers, we choose to only source our parts from top global manufacturers that we trust, such as Abbott Technologies Inc. We also ensure that every part is rigorously tested, inspected, and cross-referenced before being shipped. Peruse our inventory at your leisure to find a multitude of top requested parts like 5950013574205, and our team is ready to serve as your strategic sourcing partner today. (CAGE Code 58910).
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-357-4205 Item Description: Transformer Power | 5950 | 013574205 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
10037869-1 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT AND VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 10.250 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.280 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.300 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 5.700 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 900.0 VOLT-AMPERE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 50.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 4.5 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 720.0 WATTS SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 116.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
TEST | TEST DATA DOCUMENT | 11447-10037869 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |